Structural Retrofitting · Healthcare

ESIC Hospital, Asramam

Kollam

Client type
Central government (CPWD)
Blocks
Masonry + RCC
Testing
NDT + cores

The project

The ESIC Hospital campus at Asramam, Kollam has a two-storey load-bearing masonry block (old block) and a three-storey RCC framed block. The work covers present-condition assessment, structural evaluation and a method statement for retrofitting.

The challenge

The two blocks are built in completely different ways, so one method of assessment would not fit both. A load-bearing masonry block depends on the strength of its bricks and walls, while an RCC frame depends on the quality of its concrete and the condition of its reinforcement. The hospital also had to stay in use while the survey and testing were carried out, so the work was planned around patients and staff.

Why cores as well as NDT

Rebound hammer and ultrasonic pulse velocity readings are quick and cover many members, but they are indirect: they rate concrete quality rather than measure its strength. Extracting cores from selected members gives a direct strength value, which is then used to calibrate and confirm the NDT readings across the rest of the building. That is what makes the evaluation dependable enough to base a retrofitting decision on.

Our approach

  • Collected and reviewed the available drawings and foundation details
  • Carried out a walk-through visual survey recording cracks, corrosion and dampness
  • Non-destructive testing with rebound hammer and ultrasonic pulse velocity
  • Extracted concrete cores from selected RCC members to validate the NDT results
  • Tested brick samples for compressive strength

Outcome

A separate report for each block: the masonry block report with a retrofitting method statement, and the RCC block evaluation supported by core test results.