← All projects
Structural Retrofitting · Healthcare
ESIC Building, Ezhukone
Kollam
- Client type
- Central government (CPWD)
- Testing
- Rebound hammer, UPV
- Output
- Evaluation report
The project
A structural evaluation of the ESIC Dispensary at Ezhukone, Kollam — a single-storey, load-bearing brick masonry building of about 351 m² (3,777 sq.ft) with RCC lintel bands, verandah columns and roof beams — carried out at the request of CPWD.
What we found
- Diagonal cracking over wall openings, consistent with settlement of lintel beams, and loss of brick masonry around windows
- Moisture ingress from the roof and sunshades, with corrosion of lintel-beam reinforcement
- Rebound hammer readings rated the RCC members 'Fair' to 'Good', but direct-method UPV rated all of them 'Doubtful'
- A trial pit exposed a sound stepped footing with no signs of settlement
- Bricks tested at about 8.26 N/mm² (Class 75 to IS 1077), giving a comfortable margin on wall stresses
Recommendations
- Close and rebuild damaged openings with fresh masonry, with propping during the work
- Replaster cracked areas with woven glass-fibre fabric reinforcement
- Provide a sloped sheet roof over the terrace to stop water ingress, and treat corroded reinforcement
Outcome
An evaluation report with distress mapping, NDT and material test results, a masonry stress check and a clear repair methodology for CPWD.
Structural system
- Foundation
- Stepped masonry footing (verified by trial pit)
Site photos